Installation
Heating
Requirements
A simple calculation can
be made regarding the total amount of heat required in
any given area, by using the watts/m2 guideline below.
Chose the nearest figure to the application of work
undertaken and premises type, then multiply this by the
total area in m2. This will give you an idea as to the
total amount of wattage required for heating this area.
The size and type of
heaters can then be compared using the second
table below

Spot
Heating
As an additional guide to
spot heating, we recommend heating from two directions
to ensure good area coverage from either side. This will
ensure an overall feeling of comfort and warmth. A heat
loading of 250-300W/m2
can be considered as a guide for this type of area.

Please note
If Overhead mounting Ceramic heaters they must still be
at a minimum of 30° from the
horizontal.

Each ceramic element
can be either 220/240v or 110/120v and 1000w or 1500w. |